Voltronic Axpert Ultra 8Kw 48 8000 Watt 48 Volt Inverter Off Grid Solar Island
€972,40
Voltronic Axpert MAX II 10000-48 Inverter 10kw single-phase 48Volt solar photovoltaic for off-grid stand-alone systems
• Status indication with RGB lights
• Integrated Wi-Fi for mobile monitoring (Android / iOS app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485, CAN-BUS or RS232)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable timer and priority of use of the AC / PV output
• High power selectable charging current
• Selectable input voltage range for home appliances and personal computers
• Communication with BMS battery Pylontech US2000 / US3000, Solarpower24 2.4kw / 4.8kw
• Compatible with mains or generator input
• Built-in dustproof kit
• Optional DC output for DC fan, LED bulb, router and so on.
• Parallel operation with 6 units
- Description
- Additional information
- Download Documents
Description
Voltronic Axpert Ultra 8Kw 8000-48 Inverter 8kw single phase 48Volt solar photovoltaic for off-grid island systems
- Pure sine wave inverter
- Integrated LED bars to indicate power source and power flow
- Touch button with seven-page color LCD display
- Built-in Wi-Fi for mobile monitoring and OTA firmware update (APP required)
- Supports USB On-the-Go function
- Integrated current transformer sensor to meet self-consumption applications
- Dual outputs for intelligent load management
- Two independent AC power sources connected and switched automatically
- Configurable timers and output utilization priorities
- Configurable charger source priority
- Configurable battery charging current
- Reserved communication ports for BMS (RS485)
- Confidential external BTS detection (battery temperature sensor).
- Optional GFCI reserved, rapid stop, AFCI detections.
- Integrated anti-creep kit
SPECIFICATIONS
Table 1 Specifications of line mode
MODEL |
8KW |
Input voltage waveform |
Sinusoidal (utility or generator) |
Rated input voltage |
230 Vac |
|
170 Vac± 7 V (utility) 90Vac± 7V (generator) |
|
180Vac ± 7V (utility) ; 100Vac ± 7V (generator) |
Loss high Voltage |
280 Vac± 7 V |
High-loss return voltage |
270 Vac± 7 V |
Maximum AC input voltage |
300 Vac |
Maximum AC input current |
60A |
Second maximum input current |
60A |
Second maximum output current |
60A |
Nominal input frequency |
50 Hz/60 Hz (automatic detection) |
Low frequency loss |
40 ± 1Hz |
|
42 ± 1Hz |
Frequency of loss high |
65 ± 1Hz |
Loss high Frequency of return |
63 ± 1Hz |
Output short circuit protection |
Line mode: circuit breaker (70 A) Battery mode: electronic circuits |
Efficiency (line mode) |
>95% (rated R load, fully charged battery) |
Transfer time |
10 ms typical (UPS); 20 ms typical (Household appliances) |
Downgrading of power output: When the AC input voltage is less than 170V, the output power will be reduced. |
Table 2 Specifications of inverter mode
MODEL |
8KW |
Rated output power |
8000W |
Output voltage waveform |
Pure sine wave |
Adjusting the output voltage |
230Vac± 5 % |
Output frequency |
60Hz or 50Hz |
|
93% |
Protection from overload |
100ms@≥180% load ; 5s@≥120% load ; 10 seconds at 105%~120% of load |
Peak capacity |
2* rated power for 5 seconds |
Low DC warning voltage |
|
@ load< 20% |
46,0 Vcc |
@ 20% ≤ load< 50% |
42 . 8 Vcc |
@ load ≥ 50% |
40 . 4 Vcc |
DC warning return voltage low |
|
@ load< 20% |
48,0 Vcc |
@ 20% ≤ load< 50% |
44 . 8 Vcc |
@ load ≥ 50% |
42 . 4 Vcc |
|
|
@ load< 20% |
44,0 Vcc |
@ 20% ≤ load< 50% |
40 . 8 Vcc |
@ load ≥ 50% |
38 . 4 Vcc |
High DC Recovery voltage |
63 VDC |
High DC interruption voltage |
6 6 Vcc |
DC voltage accuracy |
+/-0.3 V@ without load |
THDV |
<5% for linear load, <10% for nonlinear load at rated voltage |
Deviation CC |
≦ 100mV |
Power limitation When the battery voltage is less than 50V DC, the output power will be derated. If the connected load is higher than this derated power, the AC output voltage will decrease until the output power is reduced to this derated power. The minimum AC output voltage corresponds to the output voltage setting – 1 0 V. |
Table 3 Charging mode specifications
Utility charging mode |
||
MODEL |
8KW |
|
Charging current (UPS) @ Rated input voltage |
120A |
|
Block charge voltage |
Flooded battery |
58.4 V DC |
Battery AGM/Gel |
56.4 V DC |
|
Floating charge voltage |
54 V DC |
|
Overload protection |
66 V DC |
|
Charging algorithm |
3 steps |
|
Charge curve |
||
Solar entrance |
||
MODEL |
8KW |
|
Nominal power |
10000W |
|
Maximum. Open circuit voltage of the photovoltaic generator |
500 V DC |
|
MPPT voltage range of the photovoltaic array |
90 V DC ~ 450 V DC |
|
Maximum. Input current |
27Ax2(MAXIMUM 40A) |
|
Max . Charging current |
150A |
|
Starting voltage |
80 V +/- 5 V DC |
|
Power limitation |
Table 4 General Specifications
MODEL |
8KW |
Safety certification |
THERE IS |
Operating temperature range |
from -1 0°C to 50°C |
Storage temperature |
-15°C~60°C |
Moisture |
5% to 95% relative humidity (no condensation) |
Dimensions ( P *W*H) , mm |
147.4x440x553.6 |
Net weight, kg |
19.5 |
Table 5 Parallel specifications
Maximum parallel numbers |
6 |
Circulating current under no-load condition |
Maximum 2A |
Power imbalance ratio |
<5% at 100% load |
Parallel communication |
POWER |
Parallel mode transfer time |
Maximum 50 ms |
Parallel kit |
YES |
Note: Parallel functionality will be disabled when only PV power is available.
.
The product is saleable with vat reduced to 10% only to Italian residents with shipping to italy. In case of foreign customers, the site will recalculate according to the vat rate of the destination country
THE FORM CAN BE FOUND HERE
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED
TO EMAIL ADDRESS moduloiva@solarpower24.it or by fax to 0545030125
Download Documents
Manual SP24/Voltronic Ultra 8KW ITA
Manuale SP24/Voltronic Ultra 8KW ITA
Manual SP24/Voltronic Ultra 8KW EN
Manual SP24/Voltronic Ultra 8KW EN
Manual SP24/Voltronic Ultra 8KW DE