Description

SP24 Axpert VM IV TWIN 4Kw 24V 4000-24 Inverter Solar Island Off Grid

– Alternating Current Power 4kw
• Installable power 5kw panels
• Support for 24V battery packs
– Built-in Wi-Fi for mobile monitoring (Android/Iphone app available)
• Supports USB On-the-Go function
– Reserved communication port for BMS (RS485) support x Pylontech UP2500, Yilink 100Ah 24v
• Replaceable fan design for ease of maintenance
• Supply the load from the grid or the PV, even if the battery is not available
• Use timer and priority of AC / PV configurable outputs
• High power selectable charging current
• Selectable input voltage range for household appliances and personal computers
• Compatible with mains supply or generator input
• Automatic restart while AC is recovering
• Cold start function

TECHNICAL SPECIFICATIONS

Table 1 Line Mode Specifications

MODEL

4KW

6KW

Input voltage waveform

Sinusoidal (AC mains or generator)

Rated input voltage

230Vac

Low voltage loss

170Vac ± 7V (UPS);

90Vac ± 7V (equipment)

Low Return Voltage Drop

180Vac ± 7V (UPS);

100Vac ± 7V (Equipment)

High Voltage Drop

280Vac ± 7V

High Return Voltage Drop

270Vac ± 7V

Max. AC input voltage

300Vac

Rated input frequency

50Hz / 60Hz (Auto Detect)

Low Frequency Drop

40 ± 1 Hz

Low Return Voltage Drop

42 ± 1 Hz

High Frequency Drop

65 ± 1 Hz

High Return Voltage Drop

63 ± 1 Hz

Short circuit protection at the output

Differential switch

Efficiency (Line Mode)

>95% (Rated load R, battery fully charged)

Transfer duration

10ms typical (UPS);

20ms typical (equipment);

Reduction of output power

If the AC input voltage drops to 170V, the output power will be reduced.

Table 2 Inverter Mode Specifications

MODEL

4KW

6KW

Rated output power

4KVA/4KW

6KVA/6KW

Output voltage waveform

Pure sine wave

Output voltage regulation

230Vac±10%

Output frequency

50 Hz

Peak efficiency

93%

Overload protection

5s@≥110% load; 10s@105~110% load

Overload capacity

2 * Rated power for 5 seconds

Max. AC output current

30Amp

40Amp

Nominal DC input voltage

24Vdc

48Vdc

Cold start voltage

23.0Vdc

46.0Vdc

Low DC alarm voltage

@ load< 50%

23.0Vdc

46.0Vdc

@ load ≥ 50%

22.0Vdc

44.0Vdc

Low Voltage Return DC Alarm

@ load< 50%

23.5Vdc

47.0Vdc

@ load ≥ 50%

23.0Vdc

46.0Vdc

Low Cutoff Voltage DC

@ load< 50%

21.5Vdc

43.0Vdc

@ load ≥ 50%

21.0Vdc

42.0Vdc

High recovery DC voltage

32Vdc

62Vdc

High DC cutoff voltage

33Vdc

63Vdc

Consumption without load

<40W

<55W

Table 3 Charge Mode Specifications

AC Grid Load Mode

MODEL

4KW

6KW

Charging current (UPS)

@ Nominal input voltage

100Amp (@V I / P = 230Vac)

Bulk Charge Voltage

Flooded battery

29,2

58.4Vdc

AGM / Gel battery

28,2

56.4Vdc

Charging float voltage

27Vdc

54Vdc

Charging algorithm

3-Step

Charge curve


Solar entrance

MODEL

4KW

6KW

Max. PV array power

5000W

6000W

Max. PV Current

27A

Nominal PV voltage

320Vdc

360Vdc

Starting voltage

60Vdc +/- 10Vdc

PV array MPPT voltage range

60Vdc~450Vdc

Max. PV array open circuit voltage

500Vdc

Maximum charge current

(AC charger plus solar charger)

120Amp

Table 4 General Specifications

MODEL

4KW

6KW

Operating temperature range

– 10 ° C + 50 ° C

Storage temperature

-15 ° C ~ 60 ° C

Humidity

5 – 95% relative humidity (non-condensing)

Dimensions (P * W * H), mm

119 x 313.6 x 457.5

Net weight, kg

10

12

.
The product can be sold with VAT reduced to 10% exclusively to Italian residents with shipping to Italy. In case of foreign customers, the site will recalculate according to the vat rate of the destination country
THE FORM YOU CAN FIND HERE
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED
AT EMAIL ADDRESS moduloiva@solarpower24.it or by fax at 0545030125

Additional information

Weight 15 kg
Vat Rate

,

Download Documents

Manual SP24_Axpert_VM_IV_TWIN_ITA

Manuals SP24_Axpert_VM_IV_TWIN_ENG