Yilink Batteria LifePo4 2.56Kw 100A 24v versione Rack 4U
€968,00
- Descrizione
- Informazioni aggiuntive
- Download Documenti
Descrizione
Yilink Batteria LifePo4 2.56Kw 100A 24v versione Rack 4U
Dotata di proprio BMS, può essere utilizzata con qualsiasi inverter a 24v.
Possibilità di collegamento cavo di comunicazione BMS con gli inverter Voltronic (tutti i modelli dotati di porta BMS) quali Axpert King, Vm III, Vm IV, Mks III, Mks IV, Axpert Max (tutti i modelli 24v)
Battery Pack Parameters
No.
|
Items
|
General Parameter
|
Remark
|
|
1 |
Combination method |
8S |
|
|
2 |
Nominal Voltage |
25.6V |
|
|
3 |
Rated Capacity |
Typical |
100Ah |
|
Minimum |
100Ah |
|||
4 |
Energy |
2560Wh |
|
|
5 |
Factory Voltage |
25.6~27.2V |
Mean Operation Voltage |
|
6 |
Voltage at end of Discharge |
20~22.4V |
Discharge Cut-off Voltage |
|
7 |
Voltage at end of Charge |
28~29.6V |
Charge Cut-off Voltage |
|
8 |
Standard charge |
Constant Current 20A Constant Voltage see No.7 0.02CA cut-off |
Charge time : Approx 5~6 h |
|
9 |
Limiting current |
20A |
BMS Limited (Charge current is ≥100A to open the current Limit) |
|
10 |
Standard discharge |
Constant current:20A end voltage see NO.6 |
|
|
11 |
Maximum Continuous Charge Current |
100A |
50ºC≥T≥5ºC |
|
12 |
Maximum Continuous Discharge Current |
100A |
55ºC≥T≥0ºC |
|
13 |
Operation Temperature Range |
Charge:0~55℃ |
60±25%R.H. No matter what mode the battery is in, once the temperature is found to exceed the absolute temperature range, stop charging or discharging immediately |
|
Discharge:–20~60℃ |
||||
14 |
Storage Temperature Range |
Less than 6 months: -10~35℃ |
60±25%R.H. at the shipment state |
|
Less than 3 months: -10~45℃ |
||||
Less than 1 months: -20~55℃ |
||||
15 |
Dimensions(W*D*H) |
442*280*178mm |
Include case |
|
16 |
Net Weight |
27Kg |
Include case |
|
17 |
Internal Impedance |
≤40mΩ |
Internal resistance measured at AC 1KHZ after 50% charge. The measure must uses the new batteries that within one week after shipment and cycles less than 5 times. |
Battery Management System
Function
|
||
Alarm |
Cell over-charge voltage |
Cell charge low temperature |
Cell over-discharge voltage |
Cell charge over temperature |
|
Pack over-charge voltage |
Cell discharge low temperature |
|
Pack over-discharge voltage |
Cell discharge over temperature |
|
Over-current charge |
Environment low temperature |
|
Over-current discharge |
Environment over temperature |
|
Mos over temperature |
|
|
Protection |
Cell over-charge voltage |
Cell charge over temperature |
Cell over-discharge voltage |
Cell discharge low temperature |
|
Pack over-charge voltage |
Cell discharge over temperature |
|
Pack over-discharge voltage |
Environment low temperature |
|
Over-current charge |
Environment over temperature |
|
Over-current discharge |
Short circuit |
|
Mos over temperature |
Fault |
|
Cell charge low temperature |
|
|
Others |
Cell balance function |
|
Communicate function |
||
Total capacity function |
||
Storage history function |
||
Current limiting function |
||
Dry contact function |
No.
|
Items
|
Description
|
1 |
+ Power terminal |
Power cable terminals: one connect to equipment, the other one paralleling to other battery module for capacity expanding |
2 |
– Power terminal |
|
3 |
LCD Screen |
Display the battery’s data |
4 |
Power Switch |
To turn ON/OFF while battery |
5 |
Working indicator light |
Display state information |
6 |
ALM alarm indicator light |
Red-trouble-light on |
7 |
Capacity volume indicator |
Display the battery’s capacity |
8 |
Reset Key |
Sleep /Activation /Reset |
9 |
ADS Dialer |
4 ADD switches, to definite different address code for each battery module when multiple modules are cascaded, up to 15 addresses |
10 |
Dry Contact Terminal |
1/2 Normally open, closed during fault protection; 3/4 Normally open, closed when a low battery alarm |
11 |
RS485 |
RJ45 Port,used to connect to the inverter’s RS485 port |
12 |
CAN |
RJ45 Port,used to connect to the inverter’s CAN port |
13 |
RS232 |
RJ11 Port,used battery condition monitoring or manufacturer to debug or service |
14 |
RS485 |
RJ45 Port,used communication in parallel |
15 |
Grounding Point |
Safety |
Attenzione il prezzo di vendita di questi prodotti è con IVA al 10% in caso di acquisto dovrete compilare una dichiarazione che i prodotti verranno utilizzati per un impianto ad energie rinnovabili
Il prodotto è vendibile con iva ridotta al 10% esclusivamente a residenti italiani con spedizione in italia. In caso di clienti esteri il prezzo verrà ricalcolato in base alla aliquota IVA del paese di destinazione
IL MODULO LO TROVATE QUI
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
IL PRODOTTO NON POTRA’ ESSERE SPEDITO FINO ALLA RICEZIONE DEL MODULO COMPILATO
ALL’INDIRIZZO EMAIL moduloiva@solarpower24.it o per fax allo 0545030125
Download Documenti
Yilink Batteria LifePo4 versione Rack ITA
Yilink Batteria LifePo4 versione Rack ITA
Yilink Kit Batteria LifePO4 configurazione Inverter SP24/Voltronic
Yilink Kit Batteria LifePO4 installazione in parallelo
Yilink Kit Batteria LifePO4 installazione in parallelo
Yilink Batteria LifePo4 versione Rack EN
Yilink Batteria LifePo4 versione Rack EN