Voltronic Axpert VM III TWIN Kit 6000watt 48V Off-Grid Inverter and Battery LIO-II 4810
€1.859,00
- Description
- Additional information
Description
KIT Axpert VM III TWIN 6Kw 48V 6000-48 Inverter Solar Island Off Grid
+
Voltronic Lio II-4810 Lifepo4 Battery Module 5.12Kw for Voltronic inverters, SP24, EASUN, ETC.
Batteries with grounded base and stackable up to 3 modules
Inverter Specifications
– Alternating Current Power 6kw
– TWIN: 2 independent AC outputs that can be assigned different priorities
• Installable power 6kw panels
• 48V battery pack support
• Removable LCD control module with multiple communications
– Built-in Wi-Fi for mobile monitoring (Android/Iphone app available)
• Supports USB On-the-Go function
– Reserved communication port for BMS (RS485) support x Pylontech US2000/3000, Yilink 50/100/150Ah 48v, SP24 100Ah 48v
• Replaceable fan design for ease of maintenance
• Supply the load from the grid or the PV, even if the battery is not available
• Use timer and priority of AC / PV configurable outputs
• High power selectable charging current
• Selectable input voltage range for household appliances and personal computers
• Compatible with mains supply or generator input
• Automatic restart while AC is recovering
• Cold start function
TECHNICAL SPECIFICATIONS
Table 1 Line Mode Specifications
INVERTER MODEL
|
4KW
|
6KW
|
Input voltage waveform
|
Sinusoidal (AC mains or generator) |
|
Rated input voltage
|
230Vac |
|
Low voltage loss
|
170Vac ± 7V (UPS); 90Vac ± 7V (equipment) |
|
Low Return Voltage Drop
|
180Vac ± 7V (UPS); 100Vac ± 7V (Equipment) |
|
High Voltage Drop
|
280Vac ± 7V |
|
High Return Voltage Drop
|
270Vac ± 7V |
|
Max. AC input voltage
|
300Vac |
|
Rated input frequency
|
50Hz / 60Hz (Auto Detect) |
|
Low Frequency Drop
|
40 ± 1 Hz |
|
Low Return Voltage Drop
|
42 ± 1 Hz |
|
High Frequency Drop
|
65 ± 1 Hz
|
|
High Return Voltage Drop
|
63 ± 1 Hz |
|
Short circuit protection at the output
|
Differential switch |
|
Efficiency (Line Mode)
|
>95% (Rated load R, battery fully charged) |
|
Transfer duration
|
10ms typical (UPS); 20ms typical (equipment); |
|
Reduction of output power
If the AC input voltage drops to 170V, the output power will be reduced. |
Table 2 Inverter Mode Specifications
INVERTER MODEL
|
4KW
|
6KW
|
Rated output power
|
4KVA/4KW |
6KVA/6KW |
Output voltage waveform
|
Pure sine wave |
|
Output voltage regulation
|
230Vac±10% |
|
Output frequency
|
50 Hz |
|
Peak efficiency
|
93% |
|
Overload protection
|
5s@≥110% load; 10s@105~110% load |
|
Overload capacity
|
2 * Rated power for 5 seconds |
|
Max. AC output current |
30Amp |
40Amp |
Nominal DC input voltage
|
24Vdc |
48Vdc |
Cold start voltage
|
23.0Vdc |
46.0Vdc |
Low DC alarm voltage
|
23.0Vdc 22.0Vdc |
46.0Vdc 44.0Vdc |
@ load< 50% |
||
@ load ≥ 50% |
||
DC Low Return Voltage Alarm
|
23.5Vdc 23.0Vdc |
47.0Vdc 46.0Vdc |
@ load< 50% |
||
@ load ≥ 50% |
||
DC Low Voltage cutoff
|
21.5Vdc 21.0Vdc |
43.0Vdc 42.0Vdc |
@ load< 50% |
||
@ load ≥ 50% |
||
DC High Recovery Voltage
|
32Vdc |
62Vdc |
High DC cutoff voltage
|
33Vdc |
63Vdc |
Consumption without load
|
<40W |
<55W |
Table 3 Charge Mode Specifications
AC Grid Load Mode
|
|||
INVERTER MODEL
|
4KW
|
6KW
|
|
Charging algorithm
|
3-Step
|
||
Charging current AC (max.)
|
100Amp (@V I / P = 230Vac) |
||
Bulk charge voltage
|
Lead-acid battery
|
29.2Vdc |
58,4 |
AGM / Gel battery
|
28.2Vdc |
56,4 |
|
Float voltage
|
27Vdc |
54Vdc |
|
Charge curve
|
|
||
MPPT Solar Charge Mode |
|||
INVERTER MODEL
|
4KW
|
6KW
|
|
Max. PV array power
|
5000W |
6000W |
|
Max. PV Current
|
27A |
||
Nominal PV voltage
|
320Vdc |
360Vdc |
|
Starting voltage
|
60Vdc +/- 10Vdc |
||
PV array MPPT voltage range
|
60Vdc~450Vdc |
||
Max. PV array open circuit voltage
|
500Vdc |
||
Maximum charge current
(AC charger plus solar charger)
|
120Amp |
Table 4 General Specifications
INVERTER MODEL
|
4KW
|
6KW
|
Operating temperature range
|
– 10 ° C + 50 ° C |
|
Storage temperature
|
-15 ° C ~ 60 ° C |
|
Humidity
|
5 – 95% relative humidity (non-condensing) |
|
Dimensions (P * W * H), mm
|
115 x 300 x 435 |
|
Net weight, kg
|
9 |
10 |
Battery Specifications
LIO II-4810 LIFEPO4 BATTERY 5.12KW 48V
|
||
BATTERY MODULE
|
LIO II-4810
|
|
CAPACITY
|
5120Wh |
|
PARAMETERS
|
||
Norminal Voltage |
51.2VDC |
|
Full Charge Voltage(FC) |
56V |
|
Full Discharge Voltage(FD) |
42V |
|
Typical Capacity |
100 Ah |
|
Max Continuous Discharging Current |
150A |
|
Max Discharging Current |
192A at 1min |
|
Protecttion |
BMS, breaker |
|
Charge Voltage |
56V |
|
Charge Current |
20A (0.2C) |
|
Maximum Charge current |
50A (0.5C) |
|
Standard Charge method |
0.2C DC (Constant current) charge to FC, |
|
Inner Resistance |
≤20m ohm |
|
PHYSICAL
|
||
Dimension, DXWXH (mm) |
214 x 621 x 550 |
|
Net Weight (kgs) |
55 |
|
*These figures may vary depending on different AC voltage and contry regulation. |
||
Product specifications are subject to change without further notice |
.
The product can be sold with VAT reduced to 10% exclusively to Italian residents with shipping to Italy. In case of foreign customers, please visit the Inverter for EU countries section of the website
THE FORM CAN BE FOUND HERE
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
THE PRODUCT CANNOT BE SHIPPED UNTIL RECEIPT OF THE