KIT Axpert VM III TWIN 6Kw 48V 6000-48 Inverter Solar Island Off Grid
+

Voltronic Lio II-4810 Lifepo4 Battery Module 5.12Kw for Voltronic inverters, SP24, EASUN, ETC.
Batteries with grounded base and stackable up to 3 modules

Inverter Specifications

– Alternating Current Power 6kw
– TWIN: 2 independent AC outputs that can be assigned different priorities
• Installable power 6kw panels
• 48V battery pack support
• Removable LCD control module with multiple communications
– Built-in Wi-Fi for mobile monitoring (Android/Iphone app available)
• Supports USB On-the-Go function
– Reserved communication port for BMS (RS485) support x Pylontech US2000/3000, Yilink 50/100/150Ah 48v, SP24 100Ah 48v
• Replaceable fan design for ease of maintenance
• Supply the load from the grid or the PV, even if the battery is not available
• Use timer and priority of AC / PV configurable outputs
• High power selectable charging current
• Selectable input voltage range for household appliances and personal computers
• Compatible with mains supply or generator input
• Automatic restart while AC is recovering
• Cold start function

TECHNICAL SPECIFICATIONS

Table 1 Line Mode Specifications

INVERTER MODEL

 

 

4KW

 

 

6KW

 

 

Input voltage waveform

 

 

Sinusoidal (AC mains or generator)

Rated input voltage

 

 

230Vac

Low voltage loss

 

 

170Vac ± 7V (UPS);

90Vac ± 7V (equipment)

Low Return Voltage Drop

 

 

180Vac ± 7V (UPS);

100Vac ± 7V (Equipment)

High Voltage Drop

 

 

280Vac ± 7V

High Return Voltage Drop

 

 

270Vac ± 7V

Max. AC input voltage

 

 

300Vac

Rated input frequency

 

 

50Hz / 60Hz (Auto Detect)

Low Frequency Drop

 

 

40 ± 1 Hz

Low Return Voltage Drop

 

 

42 ± 1 Hz

High Frequency Drop

 

 

65 ± 1 Hz

 

 

High Return Voltage Drop

 

 

63 ± 1 Hz

Short circuit protection at the output

 

 

Differential switch

Efficiency (Line Mode)

 

 

>95% (Rated load R, battery fully charged)

Transfer duration

 

 

10ms typical (UPS);

20ms typical (equipment);

Reduction of output power

 

 

If the AC input voltage drops to 170V, the output power will be reduced.

 

Table 2 Inverter Mode Specifications

 

 

INVERTER MODEL

 

 

4KW

 

 

6KW

 

 

Rated output power

 

 

4KVA/4KW

6KVA/6KW

Output voltage waveform

 

 

Pure sine wave

Output voltage regulation

 

 

230Vac±10%

Output frequency

 

 

50 Hz

Peak efficiency

 

 

93%

Overload protection

 

 

5s@≥110% load; 10s@105~110% load

Overload capacity

 

 

2 * Rated power for 5 seconds

Max. AC output current

30Amp

40Amp

Nominal DC input voltage

 

 

24Vdc

48Vdc

Cold start voltage

 

 

23.0Vdc

46.0Vdc

Low DC alarm voltage

 

 

23.0Vdc

22.0Vdc

46.0Vdc

44.0Vdc

@ load< 50%

@ load ≥ 50%

DC Low Return Voltage Alarm

 

 

23.5Vdc

23.0Vdc

47.0Vdc

46.0Vdc

@ load< 50%

@ load ≥ 50%

DC Low Voltage cutoff

 

 

21.5Vdc

21.0Vdc

43.0Vdc

42.0Vdc

@ load< 50%

@ load ≥ 50%

DC High Recovery Voltage

 

 

32Vdc

62Vdc

High DC cutoff voltage

 

 

33Vdc

63Vdc

Consumption without load

 

 

<40W

<55W

 

Table 3 Charge Mode Specifications

 

 

AC Grid Load Mode

 

 

INVERTER MODEL

 

 

4KW

 

 

6KW

 

 

Charging algorithm

 

 

3-Step

 

 

Charging current AC (max.)

 

 

100Amp

(@V I / P = 230Vac)

Bulk charge voltage

 

 

Lead-acid battery

 

 

29.2Vdc

58,4

AGM / Gel battery

 

 

28.2Vdc

56,4

Float voltage

 

 

27Vdc

54Vdc

Charge curve

 

 

MPPT Solar Charge Mode

INVERTER MODEL

 

 

4KW

 

 

6KW

 

 

Max. PV array power

 

 

5000W

6000W

Max. PV Current

 

 

27A

Nominal PV voltage

 

 

320Vdc

360Vdc

Starting voltage

 

 

60Vdc +/- 10Vdc

PV array MPPT voltage range

 

 

60Vdc~450Vdc

Max. PV array open circuit voltage

 

 

500Vdc

Maximum charge current

 

 

(AC charger plus solar charger)

 

 

120Amp

Table 4 General Specifications

INVERTER MODEL

 

 

4KW

 

 

6KW

 

 

Operating temperature range

 

 

– 10 ° C + 50 ° C

Storage temperature

 

 

-15 ° C ~ 60 ° C

Humidity

 

 

5 – 95% relative humidity (non-condensing)

Dimensions (P * W * H), mm

 

 

115 x 300 x 435

Net weight, kg

 

 

9

10

Battery Specifications

LIO II-4810 LIFEPO4 BATTERY 5.12KW 48V

 

 

BATTERY MODULE

 

 

LIO II-4810

 

 

CAPACITY

 

 

5120Wh

PARAMETERS

 

 

Norminal Voltage

51.2VDC

Full Charge Voltage(FC)

56V

Full Discharge Voltage(FD)

42V

Typical Capacity

100 Ah

Max Continuous Discharging Current

150A

Max Discharging Current

192A at 1min

Protecttion

BMS, breaker

Charge Voltage

56V

Charge Current

20A (0.2C)

Maximum Charge current

50A (0.5C)

Standard Charge method

0.2C DC (Constant current) charge to FC,
CV (Contstant voltage FC) charge till charge current decline to <0.05C

Inner Resistance

≤20m ohm

PHYSICAL

 

 

Dimension, DXWXH (mm)

214 x 621 x 550

Net Weight (kgs)

55

*These figures may vary depending on different AC voltage and contry regulation.

Product specifications are subject to change without further notice

.
The product can be sold with VAT reduced to 10% exclusively to Italian residents with shipping to Italy. In case of foreign customers, please visit the Inverter for EU countries section of the website

THE FORM CAN BE FOUND HERE




https://www.cercastock.it/repository/_barba_srl_dich_10.pdf




THE PRODUCT CANNOT BE SHIPPED UNTIL RECEIPT OF THE

Additional information

Weight 80 kg
Vat Rate

,