Description

SP24 Axpert MAX DUPLEX 11000-48 Inverter 11.0kw 48 volts off grid island Photovoltaic inverter for off grid hybrid island system

– Two independent AC inputs (Grid and/or Generator)
• Status indication with RGB lights
• Integrated Wi-Fi for mobile monitoring (Android / iOS app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable timer and priority of use of the AC / PV output
• High power selectable charging current
• Selectable input voltage range for home appliances and personal computers
– Communication with BMS battery Pylontech US2000/US3000, SP24, Yilink
• Compatible with mains or generator input
• Built-in dustproof kit
• Optional DC output for DC fan, LED bulb, router and so on.
• Parallel operation with 6 units

TECHNICAL SPECIFICATIONS

Table 1 Line Mode Specifications

MODEL

11KW

Input voltage waveform

Sinusoidal (AC mains or generator)

Rated input voltage

230Vac

Low voltage loss

170Vac ± 7V (UPS)

90Vac ± 7V (equipment)

Low Return Voltage Drop

180Vac ± 7V (UPS);

100Vac ± 7V (Equipment)

High Voltage Drop

280Vac ± 7V

High Return Voltage Drop

270Vac ± 7V

Max. AC input voltage

300Vac

Current Max. AC input

60A

Max. output current for second port

40A

Rated input frequency

50Hz / 60Hz (Auto Detect)

Low Frequency Drop

40 ± 1 Hz

Low Return Voltage Drop

42 ± 1 Hz

High Frequency Drop

65 ± 1 Hz

High Return Voltage Drop

63 ± 1 Hz

Short circuit protection at the output

Line Mode: RCD (70A)

Battery mode: Electronic Circuits

Efficiency (Line Mode)

>95% (Rated load R, battery fully charged)

Transfer duration

10ms typical (UPS);

20ms typical (equipment);

Output power reduction:

If the AC input voltage drops below 170V, the output power will be reduced.

 

Table 2 Inverter Mode Specifications

MODEL

11KW

Rated output power

11000W

Output voltage waveform

Pure sine wave

Output voltage regulation

230Vac ± 5%

Output frequency

60Hz or 50Hz

Peak efficiency

93%

Overload protection

100ms@≥180% load;5s@≥120% load; 10s@105~120 load

Overload capacity

2 * Rated power for 5 seconds

Alarm voltage DC Low

@ load< 20%

46.0Vdc

@ 20% ≤ load< 50%

42.8Vdc

@ load ≥ 50%

40.4Vdc

Alarm Return Voltage DC Low

@ load< 20%

48.0Vdc

@ 20% ≤ load< 50%

44.8Vdc

@ load ≥ 50%

42.4Vdc

Low DC cutoff voltage

@ load< 20%

44.0Vdc

@ 20% ≤ load< 50%

40.8Vdc

@ load ≥ 50%

38.4Vdc

DC High Recovery Voltage

61Vdc

DC cutoff voltage High

63Vdc

DC voltage accuracy

+/- 0.3V @ no load

THDV

<5% for linear load,< 10% for non-linear load @ rated voltage

DC offset

100 mV

Power limitation

If the battery voltage is less than 55Vdc, the output power will be reduced. If the connected load is greater than this reduced power, the output AC voltage will decrease until the output power is reduced to this reduced power. The minimum AC output voltage is the output voltage setting-10V.

Table 3 Charge Mode Specifications

AC Grid Load Mode

MODEL

11KW

Charging current (UPS)

@ Nominal input voltage

150A

Bulk charge voltage

Lead-acid battery

58.4Vdc

AGM / Gel battery

56.4Vdc

Charging float voltage

54Vdc

Overload protection

63Vdc

Charging algorithm

3-Step

Charge curve

Solar entrance

MODEL

11KW

Nominal power

11000W

Max. PV array open circuit voltage

500Vdc

PV array MPPT voltage range

90Vdc ~ 450Vdc

Max. Input current

27A x 2 (MAX 40A)

Max. Charging current

150A

Starting voltage

80 V +/- 5Vdc

Power limitation

Table 4 General Specifications

MODEL

11KW

Safety Certification

THERE IS

Operating temperature range

– 10 ° C + 50 ° C

Storage temperature

-15 ° C ~ 60 ° C

Humidity

5 – 95% relative humidity (non-condensing)

Dimensions

(P * L * H), mm

147.4x 432.5 x 553.6

Net weight, kg

18,4

Table 5 Parallel specifications

Nr. max. in parallel

6

Circulation current under no-load conditions

Max. 2A

Power imbalance ratio

<5% @ 100% load

Parallel communication

CAN

Transfer time in parallel mode

Max.50ms

Parallel Kit

YES

Note: The parallel function will be disabled if only PV power is available

.
The product can be sold with VAT reduced to 10% exclusively to Italian residents with shipping to Italy. In case of foreign customers, the site will recalculate according to the vat rate of the destination country
THE FORM YOU CAN FIND HERE
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED
AT EMAIL ADDRESS moduloiva@solarpower24.it or by fax at 0545030125

Additional information

Weight 25 kg
Vat Rate

,