SP24 Axpert MAX 8000-48 Inverter 8.0kw 48 volts Inverter Solar Photovoltaic Island Off-Grid
€865,70
Primo Axpert MAX 8000-48 Inverter 8.0kw 48 volt off grid off grid Photovoltaic inverter for off grid hybrid systems
• Status indication with RGB lights
• Integrated Wi-Fi for mobile monitoring (Android / iOS app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485, CAN-BUS or RS232)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable timer and priority of use of the AC / PV output
• High power selectable charging current
• Selectable input voltage range for home appliances and personal computers
• Communication with BMS battery Pylontech US2000 / US3000
• Compatible with mains or generator input
• Built-in dustproof kit
• Optional DC output for DC fan, LED bulb, router and so on.
• Parallel operation with 6 units for the 7200VA / 8000VA model
- Description
- Additional information
Description
SP24 Axpert MAX 8000-48 Inverter 8.0kw 48 volts off grid island Photovoltaic inverter for off grid hybrid island system
• Status indication with RGB lights
• Integrated Wi-Fi for mobile monitoring (Android / iOS app available)
• Supports USB On-the-Go function
– Reserved communication port for BMS (RS485, RS232)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable timer and priority of use of the AC / PV output
• High power selectable charging current
• Selectable input voltage range for home appliances and personal computers
– Communication with BMS batteries VOLTRONIC, SP24, YILINK, PYLONTECH (RS485)
• Compatible with mains or generator input
• Built-in dustproof kit
TECHNICAL SPECIFICATIONS
Table 1 Line Mode Specifications
MODEL
|
3.6KW
|
7.2KW
|
8KW
|
Input voltage waveform
|
Sinusoidal (AC mains or generator) |
||
Rated input voltage
|
230Vac |
||
Low Voltage Drop
|
170Vac ± 7V (UPS) 90Vac ± 7V (equipment) |
||
Low Return Voltage Drop
|
180Vac ± 7V (UPS); 100Vac ± 7V (Equipment) |
||
High Voltage Drop
|
280Vac ± 7V |
||
High Return Voltage Drop
|
270Vac ± 7V |
||
Max voltage AC input
|
300Vac |
||
Current Max. AC input
|
40A |
60A |
|
Rated input frequency
|
50Hz / 60Hz (Auto-detection) |
||
Low Frequency Drop
|
40 ± 1Hz |
||
Low Return Voltage Drop
|
42 ± 1Hz |
||
High Frequency Drop
|
65 ± 1Hz
|
||
High Return Voltage Drop
|
63 ± 1Hz |
||
Short circuit protection at the output
|
Line Mode: Differential Battery mode: Electronic Circuits |
||
Efficiency (Line Mode)
|
>95% (Rated load R, battery fully charged) |
||
Transfer duration
|
10ms typical (UPS); 20ms typical (equipment); |
||
Output power reduction:
If the AC input voltage is less than 170V, the output power will be reduced. |
Table 2 Inverter Mode Specifications
MODEL
|
3.6KW
|
7.2KW
|
8 KW
|
Rated output power
|
3600W |
7200W |
8000W |
Output voltage waveform
|
Pure sine wave |
||
Output voltage regulation
|
230Vac ± 5% |
230Vac ± 5% |
|
Output frequency
|
60Hz or 50Hz |
||
Peak efficiency
|
91% |
93% |
|
Overload protection
|
100ms @ ≥205% load; 5s @ ≥150% load; 10s @ 110 %~150% load |
||
Overload capacity
|
2 * Rated power for 5 seconds |
||
Optional 12V DC output
|
|||
DC output
|
12 VDC ± 7%, 100W |
||
High DC cutoff voltage
|
33Vdc |
66Vdc |
|
Low DC cutoff voltage
|
22Vdc |
44Vdc |
|
Nominal DC input voltage
|
24Vdc |
48Vdc |
|
Cold start voltage
|
23.0Vdc |
46.0Vdc |
|
Low DC alarm voltage
|
|
|
|
@ load< 20% |
23.0Vdc |
46.0Vdc |
|
@ 20% ≤ load< 50% |
21.4Vdc |
42.8Vdc |
|
@ load ≥ 50% |
20.2Vdc |
40.4Vdc |
|
Low DC Alarm Return Voltage
|
|
|
|
@ load< 20% |
24.0Vdc |
48.0Vdc |
|
@ 20% ≤ load< 50% |
22.4Vdc |
44.8Vdc |
|
@ load ≥ 50% |
21.2Vdc |
42.4Vdc |
|
Low DC cutoff voltage
|
|
|
|
@ load< 20% |
22.0Vdc |
44.0Vdc |
|
@ 20% ≤ load< 50% |
20.4Vdc |
40.8Vdc |
|
@ load ≥ 50% |
19.2Vdc |
38.4Vdc |
|
High DC Recovery Voltage
|
32Vdc |
64Vdc |
|
High DC cutoff voltage
|
33Vdc |
66Vdc |
|
DC voltage accuracy
|
+/- 0.3V @ no load |
||
THDV
|
<5% for linear load,< 10% for non-linear load @ rated voltage |
||
DC offset
|
≦ 100mV |
Table 3 Charge Mode Specifications
AC Grid Load Mode |
||||||
MODEL
|
3.6KW
|
7.2KW
|
8KW
|
|||
Charging current (UPS)
@ Nominal input voltage
|
80A |
120A |
||||
Bulk Charge Voltage
|
Lead-acid battery
|
29.2Vdc |
58.4Vdc |
|||
AGM / Gel battery
|
28.2Vdc |
56.4Vdc |
||||
Charging float voltage
|
27Vdc |
54Vdc |
||||
Overload protection
|
33Vdc |
66Vdc |
||||
Charging algorithm
|
3 step |
|||||
Charge curve
|
||||||
Solar entrance |
||||||
MODEL
|
3.6KW
|
7.2KW
|
8KW
|
|||
Nominal power
|
4000W |
8000W |
||||
Max. PV Array Open Circuit Voltage
|
500Vdc |
500Vdc |
||||
PV array MPPT voltage range
|
120Vdc ~ 450Vdc |
90Vdc ~ 450Vdc |
||||
Max. Input Current
|
18A |
18A x 2 |
||||
Starting voltage
|
150V +/- 5Vdc |
80V +/- 5Vdc |
||||
Power limitation
|
Table 4 General Specifications
MODEL
|
3.6KW
|
7.2KW
|
8KW
|
Safety Certification
|
THERE IS |
||
Operating temperature range
|
-10 ° C – 50 ° C |
||
Storage temperature
|
-15 ° C ~ 60 ° C |
||
Humidity
|
5 – 95% relative humidity (non-condensing) |
||
Dimensions
(P * L * H), mm
|
147.4x 432.5 x 553.6 |
||
Net weight, kg
|
14.1 |
18.4 |
Table 5 Parallel Specifications (Parallel Model Only)
Nr. max. in parallel
|
6 |
Circulation current under no-load conditions
|
Max. 2A |
Power imbalance ratio
|
<5% @ 100% load |
Parallel communication
|
CAN |
Transfer time in parallel mode
|
Max.50ms |
Parallel Kit
|
YES |
Note: The parallel function will be disabled if only PV power is available
.
The product can be sold with VAT reduced to 10% exclusively to Italian residents with shipping to Italy. In case of foreign customers, please visit the Inverter for EU countries section of the website
THE FORM YOU CAN FIND HERE
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED
TO THE EMAIL ADDRESS ebay.barbasrl@gmail.com or by fax to 0545030125