Kit SP24 Axpert Max Duplex 11Kw 48V Off-Grid Inverter and 2 x Ufo Power Wall 200Ah (20 Kw of Storage)
€5.074,30
- Description
- Additional information
Description
KIT Axpert Max Duplex 11Kw 48V 8000-48 Inverter Solar Island Off Grid
+
2 x UFO Source Wall LifePO4 200Ah 48V 9.6Kw Battery for Solar Photovoltaic Systems
-battery with multiprotocol BMS for inverters of multiple brands including SP24, Voltronic (LIB protocol), Pylontech protocol both RS485 and CAN
SP24 Axpert MAX DUPLEX 11000-48 Inverter 11.0kw 48 volts off grid island Photovoltaic inverter for off grid hybrid island system
– Two independent AC inputs (Grid and/or Generator)
• Status indication with RGB lights
• Integrated Wi-Fi for mobile monitoring (Android / iOS app available)
• Supports USB On-the-Go function
• Communication port reserved for BMS (RS485)
• Replaceable fan design for ease of maintenance
• Battery independent design
• Configurable timer and priority of use of the AC / PV output
– Selectable high-power charge current
• Selectable input voltage range for home appliances and personal computers
– Communication with BMS battery Pylontech US2000/US3000, SP24, Yilink
• Compatible with mains or generator input
• Built-in dustproof kit
• Optional DC output for DC fan, LED bulb, router and so on.
– Single-phase with dual 5500w MPPT regulator-Parallel operation with 6 units
TECHNICAL SPECIFICATIONS
Table 1 Line Mode Specifications
MODEL |
11KW |
Input voltage waveform |
Sinusoidal (AC mains or generator) |
Rated input voltage |
230Vac |
Low voltage loss |
170Vac ± 7V (UPS) 90Vac ± 7V (equipment) |
Low Return Voltage Drop |
180Vac ± 7V (UPS); 100Vac ± 7V (Equipment) |
High Voltage Drop |
280Vac ± 7V |
High Return Voltage Drop |
270Vac ± 7V |
Max. AC input voltage |
300Vac |
Current Max. AC input |
60A |
Max. output current for second port |
40A |
Rated input frequency |
50Hz / 60Hz (Auto Detect) |
Low Frequency Drop |
40 ± 1 Hz |
Low Return Voltage Drop |
42 ± 1 Hz |
High Frequency Drop |
65 ± 1 Hz |
High Return Voltage Drop |
63 ± 1 Hz |
Short circuit protection at the output |
Line Mode: RCD (70A) Battery mode: Electronic Circuits |
Efficiency (Line Mode) |
>95% (Rated load R, battery fully charged) |
Transfer duration |
10ms typical (UPS); 20ms typical (equipment); |
Output power reduction: If the AC input voltage drops below 170V, the output power will be reduced. |
|
Table 2 Inverter Mode Specifications
MODEL |
11KW |
Rated output power |
11000W |
Output voltage waveform |
Pure sine wave |
Output voltage regulation |
230Vac ± 5% |
Output frequency |
60Hz or 50Hz |
Peak efficiency |
93% |
Overload protection |
100ms@≥180% load;5s@≥120% load; 10s@105~120 load |
Overload capacity |
2 * Rated power for 5 seconds |
Alarm voltage DC Low |
|
@ load< 20% |
46.0Vdc |
@ 20% ≤ load< 50% |
42.8Vdc |
@ load ≥ 50% |
40.4Vdc |
Alarm Return Voltage DC Low |
|
@ load< 20% |
48.0Vdc |
@ 20% ≤ load< 50% |
44.8Vdc |
@ load ≥ 50% |
42.4Vdc |
Low DC cutoff voltage |
|
@ load< 20% |
44.0Vdc |
@ 20% ≤ load< 50% |
40.8Vdc |
@ load ≥ 50% |
38.4Vdc |
DC High Recovery Voltage |
61Vdc |
DC cutoff voltage High |
63Vdc |
DC voltage accuracy |
|
THDV |
<5% for linear load,< 10% for non-linear load @ rated voltage |
DC offset |
≦100 mV |
Power limitation If the battery voltage is less than 55Vdc, the output power will be reduced. If the connected load is greater than this reduced power, the output AC voltage will decrease until the output power is reduced to this reduced power. The minimum AC output voltage is the output voltage setting-10V. |
|
Table 3 Charge Mode Specifications
AC Grid Load Mode |
|||
MODEL |
11KW |
||
Charging current (UPS) @ Nominal input voltage |
150A |
||
Bulk charge voltage |
Lead-acid battery |
58.4Vdc |
|
AGM / Gel battery |
56.4Vdc |
||
Charging float voltage |
54Vdc |
||
Overload protection |
63Vdc |
||
Charging algorithm |
3-Step |
||
Charge curve |
|
||
Solar entrance |
|||
MODEL |
11KW |
||
Nominal power |
11000W |
||
Max. PV array open circuit voltage |
500Vdc |
||
PV array MPPT voltage range |
90Vdc ~ 450Vdc |
||
Max. Input current |
27A x 2 (MAX 40A) |
||
Max. Charging current |
150A |
||
Starting voltage |
80 V +/- 5Vdc |
||
Power limitation |
|
||
Table 4 General Specifications
MODEL |
11KW |
Safety Certification |
THERE IS |
Operating temperature range |
– 10 ° C + 50 ° C |
Storage temperature |
-15 ° C ~ 60 ° C |
Humidity |
5 – 95% relative humidity (non-condensing) |
Dimensions (P * L * H), mm |
147.4x 432.5 x 553.6 |
Net weight, kg |
18,4 |
Table 5 Parallel specifications
Nr. max. in parallel |
6 |
Circulation current under no-load conditions |
Max. 2A |
Power imbalance ratio |
<5% @ 100% load |
Parallel communication |
CAN |
Transfer time in parallel mode |
Max.50ms |
Parallel Kit |
YES |
Note: The parallel function will be disabled if only PV power is available
UFO Source Wall LifePO4 200Ah 48V 9.6Kw Battery for Solar Photovoltaic Systems
-battery with multiprotocol BMS for inverters of multiple brands including SP24, Voltronic (LIB protocol), Pylontech protocol both RS485 and CAN
here is the complete list
Model of battery pack
|
WL-P48200
|
Nominal voltage |
LFP battery 48V |
Rated capacity |
200AH |
Rated reserved energy |
9600WH |
Standard charging current |
0.2C |
Total charging cut-off voltage |
52.50V |
Cut-off voltage of charging monomer |
3.5V |
Standard discharging current |
0.2C |
Maximum continuous discharging current |
100A |
Cut-off voltage of discharging monomer |
2.5V |
Charging temperature range |
-5℃~55℃ |
Discharging temperature range |
-20℃~65℃ |
Dimension (W×D×H) |
490*650*250mm (excluding hanger and Anderson connector) |
Weight |
88kg |
Compound mode |
15 strings |
Storage temperature |
0℃~40℃ |
Differential pressure |
Differential pressure at the discharging end (2.5V for monomer) ≤300mV Differential pressure at the charging end (3.65V for monomer)≤300mV |
Attention in case of purchasing the product with 10% VAT you will have to fill out a declaration that the products will be used for a renewable energy system
The product is saleable with vat reduced to 10% only to Italian residents with shipping to italy. In case of foreign customers, the site will recalculate according to the vat rate of the destination country
THE FORM CAN BE FOUND HERE
https://www.cercastock.it/repository/_barba_srl_dich_10.pdf
THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED
TO EMAIL ADDRESS moduloiva@solarpower24.it or by fax to 0545030125