Sale

Kit Axpert VM II 5.0Kw 48V Off-Grid Inverter and 1 x Yilink 50ah 48v 2.4Kwh Battery

0 out of 5

1.034,00

Offer Ends In:
9Days16Hours10Minutes06Seconds
SKU: N/A Categories: ,
Clear

Description

Kit Axpert VM II 5.0Kw 48V Off-Grid Inverter and 1 x Yilink 50ah 48v 2.4Kw Battery

 

INVERTER Voltronic AXPERT VM II Premium 5000-48
– Alternating Current Power 5kw
– 48V battery pack support
– Installed Power Panels 5kw
– Pure sine wave solar inverter
– Selectable high-power charge current
– Wide DC input range (up to 500 volts VOC)
– AC / Solar input priority configurable via LCD setting
– BMS Rs485 communication port (compatible with VOLTRONIC, SP24,PYLONTECH, YILINK batteries)

Yilink Battery LifePo4 2.4Kw 50A 48v Rack 3U version

Equipped with its own BMS, it can be used with any 48v inverter.
Possibility of BMS communication cable connection with Voltronic inverters (all models with BMS port) such as Axpert King, Vm III, Vm IV, Mks III, Mks IV, Axpert Max (all 48v models) and Max II

Battery Pack Parameters

No.

 

 

Items

 

 

General Parameter

 

 

Remark

 

 

1

Combination method

15S

2

Nominal Voltage

48V

 

3

 

Rated Capacity

Typical

50Ah

Minimum

50Ah

4

Energy

2400Wh

5

Factory Voltage

48~51V

Mean Operation Voltage

6

Voltage at end of Discharge

37.5~42V

Discharge Cut-off Voltage

7

Voltage at end of Charge

52.5~55.5V

Charge Cut-off Voltage

 

8

 

 

Standard charge

Constant Current 10A Constant Voltage see No.7

0.02CA cut-off

 

Charge time : Approx 5~6 h

9

 

Limiting current

20A

BMS Limited (Charge current is

≥50A to open the current Limit)

10

Standard discharge

Constant current10A end voltage see NO.6

11

Maximum Continuous Charge Current

50A

50ºC≥T≥5ºC

12

Maximum Continuous Discharge Current

50A

55ºC≥T≥0ºC

 

 

 

13

 

 

Operation Temperature Range

Charge:0~55

60±25%R.H.

No matter what mode the battery is in, once the temperature is found to exceed the absolute temperature range, stop charging or discharging immediately

 

 

Discharge:20~60

 

 

14

 

 

Storage Temperature Range

Less than 6 months: -10~35

 

60±25%R.H.

at the shipment state

Less than 3 months: -10~45

Less than 1 months: -20~55

15

Dimensions(W*D*H)

442*480*133mm

Include case

16

Net Weight

27Kg

Include case

 

 

 

 

17

 

 

 

 

Internal Impedance

 

 

 

≤50mΩ

Internal resistance measured at AC 1KHZ after 50% charge.

The measure must uses the new batteries that within one week after shipment and cycles less than 5

times.

Battery Management System

 

Function

 

 

 

 

 

 

 

Alarm

Cell over-charge voltage

Cell charge low temperature

Cell over-discharge voltage

Cell charge over temperature

Pack over-charge voltage

Cell discharge low temperature

Pack over-discharge voltage

Cell discharge over temperature

Over-current charge

Environment low temperature

Over-current discharge

Environment over temperature

Mos over temperature

 

 

 

 

 

Protection

Cell over-charge voltage

Cell charge over temperature

Cell over-discharge voltage

Cell discharge low temperature

Pack over-charge voltage

Cell discharge over temperature

Pack over-discharge voltage

Environment low temperature

Over-current charge

Environment over temperature

Over-current discharge

Short circuit

Mos over temperature

Fault

Cell charge low temperature

 

 

 

 

Others

Cell balance function

Communicate function

Total capacity function

Storage history function

Current limiting function

Dry contact function

No.

 

 

Items

 

 

Description

 

 

1

+ Power terminal

Power cable terminals: one connect to equipment, the other one paralleling to other battery module for capacity

expanding.

2

Power terminal

3

LCD Screen

Display the battery’s data

4

Power Switch

To turn ON/OFF while battery.

5

Working indicator light

Display state information.

6

ALM alarm indicator light

Red-trouble-light on.

7

Capacity volume indicator

Display the battery’s capacity.

8

Reset Key

Sleep /Activation /Reset.

9

ADS Dialer

4 ADD switches, to define different address code for each

battery module when multiple modules are cascaded, up to 15 addresses

10

Dry Contact Terminal

1/2 Normally open, closed during fault protection;

3/4 Normally open, closed when a low battery alarm

11

RS485

RJ45 Port,used to connect to the inverter’s RS485 port

12

CAN

RJ45 Port,used to connect to the inverter’s CAN port

13

RS232

RJ11 Port,used battery condition monitoring or manufacturer to

debug or service

14

RS485

RJ45 Port,used communication in parallel

15

Grounding Point

Safety

 

Attention in case of purchasing the product with 10% VAT you will have to fill out a declaration that the products will be used for a renewable energy system
The product is saleable with vat reduced to 10% only to Italian residents with shipping to italy. In case of foreign customers, the site will recalculate according to the vat rate of the destination country

THE FORM CAN BE FOUND HERE



https://www.cercastock.it/repository/_barba_srl_dich_10.pdf



THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED


TO EMAIL ADDRESS moduloiva@solarpower24.it or by fax to 0545030125

Additional information

Weight 80 kg
Vat Rate

,