Voltronic Axpert VM II Premium 5000-48 Off-Grid Island Solar Inverter 5000 Watt 48 Volts

482,90

Primo VM-II Technical Characteristics
Template First VM-II 3000-24 First VM-II 5000-48
Potenza 3000VA / 3000W 5000VA / 5000W
AC Input (Alternating Current)
Voltage 230 VAC
Selectable Range 170-280 VAC (For Personal Computers)
90-280 VAC (For Home Appliances)
Frequency 50 Hz / 60 Hz (Auto sensing)
AC output (alternating current)
AC voltage (Solar / Battery mode) 230VAC ± 5%
Peak Power 6000VA 10000VA
Efficiency (Peak) 90% ~ 93%
Mode Change Time 15 ms (For Personal Computers)
20 ms (For Appliances)
Wave type Pure Wave
Battery
Battery voltage 24 VDC 48 VDC
Maintenance Charge Voltage 27 VDC 54 VDC
Portestion voltage 31 VDC 63 VDC
Solar and battery charger parameters
Solar Charger Type MPPT
Maximum Power Panels 4000W 4000W
MPPT Operation Voltage 120 ~ 450 VDC 120 ~ 450 VDC
Maximum VOC voltage 500 VDC
Solar Charge Current Max 80A
Charging Current AC Max 80A
Size and Weight
Depth X Height x Width (mm) 100 x 300 x 440 100 x 300 x 440
Net weight 9,0 10
Communication Interfaces USB / RS232
Operation Environment
Humidity 5% to 95% Relative Humidity (Non-condensing)
Operating temperature -10 ℃ to 50 ℃
Storage Temperature -15 ℃ to 60 ℃
* The Technical Characteristics can be changed without notice
Barba Srl
Barba Srl
Via Locchi, 3f – 47122 Forlì Via Locchi, 3f – 47122 Forlì
Tel. 0543-1995799 Tel. 0543-1995799
email: solarpower24@solarpower24.it
website: www.solarpower24.it
SKU: N/A Categories: , ,
Clear

Description

INVERTER Voltronic AXPERT VM II Premium 5000-48
• Alternating Current Power 5kw
• 48V battery pack support
• Installable power 5kw panels
• Pure sine wave solar inverter
• High power selectable charging current
– Wide DC input range (up to 500 volts VOC)
• AC / Solar input priority configurable via LCD setting
– BMS Rs485 communication port (compatible with VOLTRONIC, SP24,PYLONTECH, YILINK batteries)

For the Complete Technical Characteristics See the detail below

TECHNICAL SPECIFICATIONS

Table 1 Line Mode Specifications

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Input voltage waveform

Sinusoidal (AC mains or generator)

Rated input voltage

230Vac

Low voltage loss

170Vac ± 7V (UPS);

90Vac ± 7V (equipment)

Low Return Voltage Drop

180Vac ± 7V (UPS);

100Vac ± 7V (Equipment)

High Voltage Drop

280Vac ± 7V

High Return Voltage Drop

270Vac ± 7V

Max. AC input voltage

300Vac

Rated input frequency

50Hz / 60Hz (Auto Detect)

Low Frequency Drop

40 ± 1 Hz

Fall Return Frequency Low

42 ± 1 Hz

High Frequency Fall

65 ± 1 Hz

High Return Voltage Drop

63 ± 1 Hz

Short circuit protection at the output

Differential

Efficiency (Line Mode)

>95% (Rated load R, battery fully charged)

Transfer duration

10ms typical (UPS);

20ms typical (equipment);

Reduction of output power

If the AC input voltage drops to 170V, the output power will be reduced.

Table 2 Inverter Mode Specifications

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Rated output power

1.2KVA/ 1.2KW

2.5KVA/ 2.5KW

3KVA / 3KW

5KVA / 5KW

Output voltage waveform

Pure sine wave

Output voltage regulation

230Vac ± 5%

Output frequency

50 Hz

Peak efficiency

93%

Overload protection

5s @ ≥130% load; 10s @ 105 %~130% load

Overload capacity

2 * Rated power for 5 seconds

Nominal DC input voltage

12Vdc

24Vdc

48Vdc

Cold start voltage

11.5Vdc

23.0Vdc

46.0Vdc

Low DC alarm voltage

@ load< 50%

11.5Vdc

23.0Vdc

46.0Vdc

@ load ≥ 50%

11.0Vdc

22.0Vdc

44.0Vdc

Low DC Alarm Return Voltage

@ load< 50%

11.7Vdc

23.5Vdc

47.0Vdc

@ load ≥ 50%

11.5Vdc

23.0Vdc

46.0Vdc

Low Cutoff Voltage DC

@ load< 50%

10.7Vdc

21.5Vdc

43.0Vdc

@ load ≥ 50%

10.5Vdc

21.0Vdc

42.0Vdc

DC High Recovery Voltage

15Vdc

31Vdc

62Vdc

DC High Cutoff Voltage

16Vdc

32Vdc

63Vdc

Consumption without load

<35W

<50W

Table 3 Charge Mode Specifications

AC Grid Load Mode

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Charging algorithm

3-Step

Charging current AC (max.)

80Amp (@VI/P=230Vac)

100Amp

Bulk charge voltage

Flooded battery

14,6

29,2

58,4

AGM / Gel battery

14,1

28,2

56,4

Float voltage

13.5Vdc

27Vdc

54Vdc

Charge curve

MPPT Solar Charge Mode

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Max. PV array power

2000W

3000W

5000W

Nominal PV voltage

240Vdc

320Vdc

Starting voltage

70Vdc +/- 10Vdc

150Vdc +/- 10Vdc

PV array MPPT voltage range

60~300Vdc

60~400Vdc

120 ~ 450Vdc

Max. PV array open circuit voltage

350Vdc

450Vdc

500Vdc

Max. Input current

13Amp

18Amp

Maximum charge current

(AC charger plus solar charger)

100Amp

Table 4 General Specifications

INVERTER MODEL

1.2KVA


2

.

5KVA

3KVA

5KVA

Safety certification

THERE IS

Operating temperature range

– 10 ° C + 50 ° C

Storage temperature

-15 ° C ~ 60 ° C

Humidity

5 – 95% relative humidity (non-condensing)

Dimensions (P * W * H), mm

90 x 288 x 357

110 x 288 x 390

120 x 300 x 440

Net weight, kg

6,5

7,0

7,2

10

.
The product can be sold with VAT reduced to 10% exclusively to Italian residents with shipping to Italy. In case of foreign customers, please visit the Inverter for EU countries section of the website

THE FORM CAN BE FOUND HERE




https://www.cercastock.it/repository/_barba_srl_dich_10.pdf




THE PRODUCT CANNOT BE SHIPPED UNTIL THE COMPLETED FORM IS RECEIVED


TO EMAIL ADDRESS moduloiva@solarpower24.it or by fax to 0545030125

Additional information

Weight 12 kg
Vat Rate

,

Download Documents

Manuale SP24_Axpert_VM_II_Premium_1-5Kw_20230318_ITA

Manual SP24_Axpert_VM_II_Premium_1-5Kw_20230318_EN

Reviews

There are no reviews yet.


Be the first to review “Voltronic Axpert VM II Premium 5000-48 Off-Grid Island Solar Inverter 5000 Watt 48 Volts”